eRFID_NotificationAndErrorCodes
This page covers the description of the eRFID_NotificationAndErrorCodes enumeration
eRFID_NotificationAndErrorCodes enumeration contains a set of notification and error codes returned to the user application by calling the callback-function.
1
const eRFID_NotificationAndErrorCodes = {
2
RFID_NOTIFICATION_ERROR: 65536,
3
RFID_NOTIFICATION_DOCUMENT_READY: 65537,
4
RFID_NOTIFICATION_READ_PROTOCOL4: 65539,
5
RFID_NOTIFICATION_READ_PROTOCOL3: 65546,
6
RFID_NOTIFICATION_PROGRESS: 65547,
7
RFID_NOTIFICATION_TA_STEP: 65550,
8
RFID_NOTIFICATION_SM_REQUIRED: 65551,
9
RFID_NOTIFICATION_ISO_ERROR: 69632,
10
RFID_NOTIFICATION_PA_REQUEST: 77824,
11
RFID_NOTIFICATION_SM_ESTABLISHED: 81935,
12
RFID_NOTIFICATION_PCSC_READER_DISCONNECTED: 131072,
13
RFID_NOTIFICATION_PCSC_READER_LIST_CHANGED: 131073,
14
RFID_NOTIFICATION_PCSC_BYTES_RECEIVED: 131074,
15
RFID_NOTIFICATION_PCSC_TOTAL_READING_TIME: 131075,
16
RFID_NOTIFICATION_PCSC_DATA_RECEIVED: 131076,
17
RFID_NOTIFICATION_PCSC_BYTES_SENT: 131077,
18
RFID_NOTIFICATION_PCSC_TOTAL_READING_SPEED: 131078,
19
RFID_NOTIFICATION_PCSC_TOTAL_PROCESS_TIME: 131079,
20
RFID_NOTIFICATION_PCSC_READER_LIST_CHANGING: 131080,
21
RFID_NOTIFICATION_PCSC_EXT_LENGTH_SUPPORT: 131088,
22
RFID_NOTIFICATION_PA_CERTIFICATE_CHAIN: 131089,
23
RFID_NOTIFICATION_PA_CERTIFICATE_CHAIN_ITEM: 131090,
24
RFID_NOTIFICATION_SCENARIO: 131104,
25
RFID_NOTIFICATION_PCSC_READING_DATAGROUP: 196608,
26
RFID_NOTIFICATION_PCSC_FILE_NOT_FOUND: 262144,
27
RFID_NOTIFICATION_PCSC_END_OF_FILE: 327680,
28
RFID_NOTIFICATION_PCSC_FILE_ACCESS_DENIED: 393216,
29
RFID_NOTIFICATION_PCSC_APPLICATION_SELECTED: 458752,
30
RFID_NOTIFICATION_AC_PROCEDURE_START: 524288,
31
RFID_NOTIFICATION_AC_PROCEDURE_FINISH: 589824,
32
RFID_NOTIFICATION_PA_SECURITY_OBJECT_CHECK: 655360,
33
RFID_NOTIFICATION_PA_FILE_CHECK: 720896,
34
RFID_NOTIFICATION_PCSC_UPDATING_DATAGROUP: 786432,
35
RFID_NOTIFICATION_AUXILIARY_DATA_VALIDATION: 851968,
36
RFID_NOTIFICATION_RI_SECTOR_ID: 917504,
37
RFID_NOTIFICATION_BIOMETRICS_EMPTY_PLACEHOLDER: 983040,
38
RFID_ERROR_NO_ERROR: 1,
39
RFID_ERROR_ALREADY_DONE: 2,
40
RFID_LAYER6_FILE_EOF1: -2147458430,
41
RFID_LAYER6_PWD_DEACTIVATED: -2147458429,
42
RFID_LAYER6_PWD_BLOCKED: -2147458112,
43
RFID_LAYER6_PWD_SUSPENDED: -2147458111,
44
RFID_LAYER6_PWD_BLOCKED_2: -2147456637,
45
RFID_LAYER6_PWD_DEACTIVATED_2: -2147456636,
46
RFID_LAYER6_PWD_SUSPENDED_2: -2147456635,
47
RFID_LAYER6_MSE_SET_AT_FAILURE: -2046819578,
48
RFID_LAYER6_INCORRECT_PARAMS: -2147456384,
49
RFID_LAYER6_FILE_NOT_FOUND: -2147456382,
50
RFID_LAYER6_NO_REFERENCE_DATA: -2147456376,
51
RFID_LAYER6_FILE_EOF2: -2147456256,
52
RFID_Error_GraphManager: -2147418112,
53
RFID_ERROR_NO_CHIP_DETECTED: -2147418111,
54
RFID_ERROR_NOT_AVAILABLE: -2147418110,
55
RFID_ERROR_INVALID_PARAMETER: -2147418108,
56
RFID_ERROR_NOT_INITIALIZED: -2147418107,
57
RFID_Error_NotEnoughMemory: -2147418106,
58
RFID_ERROR_INVALID_DIRECTORY: -2147418104,
59
RFID_ERROR_UNKNOWN_COMMAND: -2147418103,
60
RFID_ERROR_FILE_IO_ERROR: -2147418102,
61
RFID_ERROR_BUSY: -2147418101,
62
RFID_ERROR_OLD_FIRMWARE: -2147418100,
63
RFID_ERROR_PCSC_FAILED: -2147352576,
64
RFID_ERROR_PCSC_READER_NOT_AVAILABLE: -2147352575,
65
RFID_ERROR_PCSC_CANT_CONNECT_CARD: -2147352574,
66
RFID_ERROR_PCSC_CARD_IS_NOT_CONNECTED: -2147352573,
67
RFID_ERROR_PCSC_OPERATION_CANCELLED: -2147352572,
68
RFID_ERROR_PCSC_CARD_IS_BUSY: -2147352571,
69
RFID_ERROR_PCSC_FAILED_S_CARD: -2147352570,
70
RFID_ERROR_PCSC_EXT_LE_FAILED: -2147352560,
71
RFID_LAYER6_PWD_FAILED: -2146409536,
72
RFID_ERROR_NOT_PERFORMED: -2097152000,
73
RFID_ERROR_SESSION_IS_CLOSED: -2097151999,
74
RFID_ERROR_SESSION_TERMINAL_UNSUPPORTED_OPERATION: -2097151998,
75
RFID_ERROR_SESSION_TERMINAL_TYPE_UNKNOWN: -2097151984,
76
RFID_ERROR_SESSION_TERMINAL_TYPE_BAD_CERTIFICATE: -2097151983,
77
RFID_ERROR_SESSION_TERMINAL_TYPE_NOT_SET: -2097151982,
78
RFID_ERROR_SESSION_PROCEDURE_TYPE_UNKNOWN: -2097151981,
79
RFID_ERROR_SESSION_PROCEDURE_TYPE_UNSUPPORTED: -2097151980,
80
RFID_ERROR_SESSION_PROCEDURE_TYPE_NOT_SET: -2097151979,
81
RFID_ERROR_SESSION_ACCESS_KEY_UNKNOWN_TYPE: -2097151978,
82
RFID_ERROR_SESSION_ACCESS_KEY_UNSUPPORTED_SM_TYPE: -2097151977,
83
RFID_ERROR_SESSION_ACCESS_KEY_INCORRECT_SM_TYPE: -2097151976,
84
RFID_ERROR_SESSION_ACCESS_KEY_RESTRICTED: -2097151975,
85
RFID_ERROR_SESSION_ACCESS_KEY_INCORRECT_DATA: -2097151974,
86
RFID_ERROR_SESSION_ACCESS_KEY_NOT_SET: -2097151973,
87
RFID_ERROR_SESSION_PWD_MANAGEMENT_NOT_AUTHORIZED: -2097151972,
88
RFID_ERROR_SESSION_ACCESS_CONTROL_UNKNOWN_TYPE: -2097151968,
89
RFID_ERROR_SESSION_ACCESS_CONTROL_REQUIRES_SM: -2097151967,
90
RFID_ERROR_SESSION_ACCESS_CONTROL_REQUIRES_PACE: -2097151966,
91
RFID_ERROR_SESSION_ACCESS_CONTROL_REQUIRES_CA_KEYS: -2097151965,
92
RFID_ERROR_SESSION_ACCESS_CONTROL_REQUIRES_TA: -2097151964,
93
RFID_ERROR_SESSION_ACCESS_CONTROL_REQUIRES_CA: -2097151963,
94
RFID_ERROR_SESSION_ACCESS_CONTROL_INCORRECT_OPTION_CA: -2097151962,
95
RFID_ERROR_SESSION_ACCESS_CONTROL_CA_FAILED: -2097151961,
96
RFID_ERROR_SESSION_ACCESS_CONTROL_TA_FAILED: -2097151960,
97
RFID_ERROR_SESSION_ACCESS_CONTROL_AA_FAILED: -2097151959,
98
RFID_ERROR_SESSION_ACCESS_CONTROL_RI_FAILED: -2097151958,
99
RFID_ERROR_SESSION_PA_SIGNATURE_CHECK_FAILED: -2097151952,
100
RFID_ERROR_SESSION_PA_HASH_CHECK_FAILED: -2097151951,
101
RFID_ERROR_SESSION_INVALID_AUX_DATA_DATE_OF_EXPIRY: -2097151936,
102
RFID_ERROR_SESSION_INVALID_AUX_DATA_DATE_OF_BIRTH: -2097151935,
103
RFID_ERROR_SESSION_INVALID_AUX_DATA_COMMUNITY_ID: -2097151934,
104
RFID_ERROR_SESSION_E_SIGN_REQUIRES_APP_SELECTION: -2097151920,
105
RFID_ERROR_SESSION_E_SIGN_PIN_NOT_SET: -2097151919,
106
RFID_ERROR_SESSION_E_SIGN_PIN_NOT_VERIFIED: -2097151918,
107
RFID_ERROR_SESSION_INCORRECT_DATA: -2097151904,
108
RFID_ERROR_SESSION_FILE_NOT_ENOUGH_DATA: -2097086464,
109
RFID_ERROR_SESSION_FILE_INCORRECT_DATA: -2097020928,
110
RFID_ERROR_SESSION_FILE_UNEXPECTED_DATA: -2096955392,
111
RFID_ERROR_SESSION_FILE_CONTENTS_UNEXPECTED_DATA: -2096889856,
112
RFID_ERROR_SESSION_FILE_WRONG_TAG: -2096824320,
113
RFID_ERROR_SESSION_FILE_CANT_USE_DATA: -2096758784,
114
RFID_ERROR_SESSION_FILE_CANT_READ_DATA: -2096693248,
115
RFID_ERROR_SESSION_FILE_ACCESS_DENIED: -2096627712,
116
RFID_LAYER6_SECURITY_MANAGER: -2046820352,
117
RFID_LAYER6_APP_SELECTION_FAILURE: -2046820351,
118
RFID_LAYER6_MUTUAL_AUTH_MAC_FAIL: -2046820096,
119
RFID_LAYER6_MUTUAL_AUTH_ENC_FAIL: -2046820095,
120
RFID_LAYER6_MUTUAL_AUTH_FAILURE: -2046820094,
121
RFID_LAYER6_SM_DO8E_MISSING: -2046819840,
122
RFID_LAYER6_SM_DO87_MISSING: -2046819839,
123
RFID_LAYER6_SM_DO99_MISSING: -2046819838,
124
RFID_LAYER6_SM_MAC_INCORRECT: -2046819837,
125
RFID_LAYER6_SM_DO87_INCORRECT: -2046819836,
126
RFID_LAYER6_NON_TLV_RESPONSE_DATA: -2046819584,
127
RFID_LAYER6_WRONG_RND_ICC_LENGTH: -2046819583,
128
RFID_LAYER6_INT_AUTH_FAILURE: -2046819582,
129
RFID_LAYER6_MSE_SET_KAT_FAILURE: -2046819581,
130
RFID_LAYER6_MSE_SET_DST_FAILURE: -2046819580,
131
RFID_LAYER6_PSO_CERTIFICATE_FAILURE: -2046819579,
132
RFID_LAYER6_GET_CHALLENGE_FAILURE: -2046819577,
133
RFID_LAYER6_EXT_AUTH_FAILURE: -2046819576,
134
RFID_LAYER6_GENERAL_AUTH_FAILURE: -2046819575,
135
RFID_ERROR_FAILED: -1,
136
}
Copied!
Constant
Description
RFID_NOTIFICATION_ERROR
error
RFID_NOTIFICATION_DOCUMENT_READY
event of appearance of RFID-chip in the scope of the reader antenna or its moving away from the scope of the reader
RFID_NOTIFICATION_READ_PROTOCOL4
event of the beginning/end of data reading from the RFID-chip via ISO/IEC 14443-4 protocol when working in the batch mode
RFID_NOTIFICATION_READ_PROTOCOL3
event of the beginning/end of data reading from the RFID-chip via ISO/IEC 14443-3 protocol.
RFID_NOTIFICATION_PROGRESS
indication of the progress of execution of data reading operation
RFID_NOTIFICATION_TA_STEP
indication of the next step of terminal authentication in Online-authentication mode
RFID_NOTIFICATION_SM_REQUIRED
event of detection of the need to organize a secure communication channel
RFID_NOTIFICATION_ISO_ERROR
event informing the user application on detection of data in compliance processed with the regulations of normative documents, errors when executing the current operation
RFID_NOTIFICATION_PA_REQUEST
request of the user-defined DS-certificate prior to the procedure of digital signature verification of EF.SOD document security object in the batch mode
RFID_NOTIFICATION_SM_ESTABLISHED
event of the result of the opening of a secure communication channel
RFID_NOTIFICATION_PCSC_READER_DISCONNECTED
event of unplugging of the RFID-chip reader
RFID_NOTIFICATION_PCSC_READER_LIST_CHANGED
event of the end of reorganization of the list of RFID-readers, working under PC/SC-driver control
RFID_NOTIFICATION_PCSC_BYTES_RECEIVED
transfer of the total amount of information received from the RFID-chip to the user application during execution of data reading operation
RFID_NOTIFICATION_PCSC_TOTAL_READING_TIME
transfer of the total time of execution of data reading operation to the user application
RFID_NOTIFICATION_PCSC_DATA_RECEIVED
transfer of the total amount of information and service groups data received from the RFID-chip to the user application during execution of data reading operation
RFID_NOTIFICATION_PCSC_BYTES_SENT
transfer of the total amount of information transmitted to the RFID-chip to the user application during execution of data reading operation
RFID_NOTIFICATION_PCSC_TOTAL_READING_SPEED
transfer of the average data reading rate to the user application
RFID_NOTIFICATION_PCSC_TOTAL_PROCESS_TIME
transfer of the total time of execution of data reading procedure to the user application
RFID_NOTIFICATION_PCSC_READER_LIST_CHANGING
event of the beginning of reorganization of the list of RFID-readers, working under PC/SC-driver control
RFID_NOTIFICATION_PCSC_EXT_LENGTH_SUPPORT
event of detection of extended length reading commands support by the RFID-chip
RFID_NOTIFICATION_PA_CERTIFICATE_CHAIN
event of the start/end of the certificate chain formation for the document security object digital signature verification as a part of passive authentication procedure
RFID_NOTIFICATION_PA_CERTIFICATE_CHAIN_ITEM
event that indicates a type of the current analyzed element of the certificate chain being composed
RFID_NOTIFICATION_SCENARIO
a request from the user application of some data or actions in a certain step of the scenario
RFID_NOTIFICATION_PCSC_READING_DATAGROUP
event of the beginning/end of file reading
RFID_NOTIFICATION_PCSC_FILE_NOT_FOUND
event of detection of file absence
RFID_NOTIFICATION_PCSC_END_OF_FILE
event of reaching the file end when performing its reading
RFID_NOTIFICATION_PCSC_FILE_ACCESS_DENIED
event of detection of absence of the file access rights
RFID_NOTIFICATION_PCSC_APPLICATION_SELECTED
event of the application selection operation
RFID_NOTIFICATION_AC_PROCEDURE_START
event of the beginning of the authentication or secure data access procedure
RFID_NOTIFICATION_AC_PROCEDURE_FINISH
event of the end of the authentication or secure data access procedure
RFID_NOTIFICATION_PA_SECURITY_OBJECT_CHECK
event of the data security object verification as part of PA
RFID_NOTIFICATION_PA_FILE_CHECK
event of the file data integrity checking as part of PA
RFID_NOTIFICATION_PCSC_UPDATING_DATAGROUP
event of the procedure of file contents updating
RFID_NOTIFICATION_AUXILIARY_DATA_VALIDATION
event of the auxiliary data verification
RFID_NOTIFICATION_RI_SECTOR_ID
event of the receiving of the sector identifier data during RI
RFID_NOTIFICATION_BIOMETRICS_EMPTY_PLACEHOLDER
event of the detection of real biometric data absence in DG3 or DG4 and random filling data usage [35, R7-p1_v2_sIII_0057, R7-p3_v2_sIII_0011]
RFID_ERROR_NO_ERROR
successful operation
RFID_ERROR_ALREADY_DONE
requested operation has already been performed
RFID_LAYER6_FILE_EOF1
attempt of reading outside the end of the file
RFID_LAYER6_PWD_DEACTIVATED
error of the execution of MSE:Set AT (when performing PACE). It means that the selected password is deactivated. It is required to perform a procedure of password activation
RFID_LAYER6_PWD_BLOCKED
error of the execution of MSE:Set AT (when performing PACE) or General Authenticate (variants of appearance are analogue to RFID_LAYER6_GE- NERAL_AUTH_ FAILURE). It means that the selected password is blocked. It is required to perform a procedure of password unblocking
RFID_LAYER6_PWD_SUSPENDED
error of the execution of MSE:Set AT (when performing PACE) or General Authenticate (variants of appearance are analogue to RFID_LAYER6_GE- NERAL_AUTH_ FAILURE). It means that the selected password is suspended. It is required to perform a procedure of password resuming
RFID_LAYER6_PWD_BLOCKED_2
error of the execution of General Authenticate APDU-command or commands of work with eSign application. It means that the selected password is blocked. It is required to perform procedure of password unblocking
RFID_LAYER6_PWD_DEACTIVATED_2
error of the execution of General Authenticate APDU-command when performing PACE procedure or commands of work with eSign application. It means that the selected password is deactivated. It is required to perform procedure of password activation
RFID_LAYER6_PWD_SUSPENDED_2
error of General Authenticate APDU-command execution when performing PACE. It means that the selected password is suspended. It is required to perform procedure of password resuming
RFID_LAYER6_MSE_SET_AT_FAILURE
error of MSE:Set AT APDU-command execution when performing the procedures:
  • PACE
  • TA
  • CA
  • RI
RFID_LAYER6_INCORRECT_PARAMS
error of the execution of MSE:Set AT (variants of appearance – see RFID_LAYER6_- MSE_SET_AT_- FAILURE description) or General Authenticate (variants of appearance – see RFID_LAYER6_- GENERAL_AUTH_- FAILURE description).
RFID_LAYER6_FILE_NOT_FOUND
file not found
RFID_LAYER6_NO_REFERENCE_DATA
unavailable data, pointed to by the APDU-command parameters
RFID_LAYER6_FILE_EOF2
attempt of reading outside the file end of the
RFID_Error_GraphManager
connection error
RFID_ERROR_NO_CHIP_DETECTED
RFID-chip is absent in the scope of the reader
RFID_ERROR_NOT_AVAILABLE
requested operation unavailable
RFID_ERROR_INVALID_PARAMETER
incorrect command parameter
RFID_ERROR_NOT_INITIALIZED
SDK control library was not initialized
RFID_Error_NotEnoughMemory
insufficient memory for command execution
RFID_ERROR_INVALID_DIRECTORY
incorrect directory name
RFID_ERROR_UNKNOWN_COMMAND
unknown command
RFID_ERROR_FILE_IO_ERROR
file input/output error
RFID_ERROR_BUSY
SDK control library is busy. Execution of the command is impossible
RFID_ERROR_OLD_FIRMWARE
it is required to update reader’s firmware
RFID_ERROR_PCSC_FAILED
error of command of data exchange with RFID-chip execution (common case)
RFID_ERROR_PCSC_READER_NOT_AVAILABLE
RFID-chip reader unavailable
RFID_ERROR_PCSC_CANT_CONNECT_CARD
failed to connect with RFID-chip
RFID_ERROR_PCSC_CARD_IS_NOT_CONNECTED
no active RFID-chip
RFID_ERROR_PCSC_OPERATION_CANCELLED
data reading operation cancelled by the user
RFID_ERROR_PCSC_CARD_IS_BUSY
data exchange with RFID-chip takes place. Execution of the command is impossible
RFID_ERROR_PCSC_FAILED_S_CARD
error of SCard service when data exchanging with RFID-chip
RFID_ERROR_PCSC_EXT_LE_FAILED
error of executing command of extended length reading. Full reinitialization of RFID-chip is required
RFID_LAYER6_PWD_FAILED
error of the execution of MSE:Set AT when performing PACE procedure or General Authenticate
(variants of appearance are analogue to RFID_ LAYER6_GENERA L_AUTH_FAILURE ). It means that incorrect password value has been used. Low order 8 bits of code contain the remaining number of attempts for this password. The user application may try to repeat an attempt of performing the required procedure with other values
RFID_ERROR_NOT_PERFORMED
operation was not performed
RFID_ERROR_SESSION_IS_CLOSED
session closed, operation impossible
RFID_ERROR_SESSION_TERMINAL_UNSUPPORTED_OPERATION
operation is not supported by the current type of terminal
RFID_ERROR_SESSION_TERMINAL_TYPE_UNKNOWN
unknown type of terminal
RFID_ERROR_SESSION_TERMINAL_TYPE_BAD_CERTIFICATE
error of reading or analysis of the terminal certificate data
RFID_ERROR_SESSION_TERMINAL_TYPE_NOT_SET
terminal type was not defined for the current session
RFID_ERROR_SESSION_PROCEDURE_TYPE_UNKNOWN
unknown authentication procedure type
RFID_ERROR_SESSION_PROCEDURE_TYPE_UNSUPPORTED
defined type terminal does not support this type of procedure
RFID_ERROR_SESSION_PROCEDURE_TYPE_NOT_SET
type of authentication procedure was not set for the current session
RFID_ERROR_SESSION_ACCESS_KEY_UNKNOWN_TYPE
unknown access key type
RFID_ERROR_SESSION_ACCESS_KEY_UNSUPPORTED_SM_TYPE
unsupported type of secure data access procedure
RFID_ERROR_SESSION_ACCESS_KEY_INCORRECT_SM_TYPE
secure data access procedure does not allow to use the given key type
RFID_ERROR_SESSION_ACCESS_KEY_RESTRICTED
key type is not supported by the current terminal type, or the rights to its use are insufficient
RFID_ERROR_SESSION_ACCESS_KEY_INCORRECT_DATA
incorrect key contents (empty or zero string)
RFID_ERROR_SESSION_ACCESS_KEY_NOT_SET
secure data access key was not set for the current session
RFID_ERROR_SESSION_PWD_MANAGEMENT_NOT_AUTHORIZED
operation of password management is not authorized for the current terminal type
RFID_ERROR_SESSION_ACCESS_CONTROL_UNKNOWN_TYPE
unknown type of the procedure of authentication or secure data access
RFID_ERROR_SESSION_ACCESS_CONTROL_REQUIRES_SM
preliminary opening of the secure data access session is required (PACE or BAC)
RFID_ERROR_SESSION_ACCESS_CONTROL_REQUIRES_PACE
preliminary opening of the secure data access session is required (PACE)
RFID_ERROR_SESSION_ACCESS_CONTROL_REQUIRES_CA_KEYS
execution of TA preliminary step (for version 2) is required – computing CA ephemeral public keys
RFID_ERROR_SESSION_ACCESS_CONTROL_REQUIRES_TA
preliminary TA procedure is required
RFID_ERROR_SESSION_ACCESS_CONTROL_REQUIRES_CA
preliminary CA procedure is required
RFID_ERROR_SESSION_ACCESS_CONTROL_INCORRECT_OPTION_CA
discrepancy between the selected CA variant on the preliminary and main stages
RFID_ERROR_SESSION_ACCESS_CONTROL_CA_FAILED
CA procedure failed
RFID_ERROR_SESSION_ACCESS_CONTROL_TA_FAILED
TA procedure failed
RFID_ERROR_SESSION_ACCESS_CONTROL_AA_FAILED
AA procedure failed
RFID_ERROR_SESSION_ACCESS_CONTROL_RI_FAILED
RI procedure failed
RFID_ERROR_SESSION_PA_SIGNATURE_CHECK_FAILED
document security object digital signature verification failed
RFID_ERROR_SESSION_PA_HASH_CHECK_FAILED
informational data group integrity verification failed
RFID_ERROR_SESSION_INVALID_AUX_DATA_DATE_OF_EXPIRY
verification of auxiliary data (date of expiry) failed
RFID_ERROR_SESSION_INVALID_AUX_DATA_DATE_OF_BIRTH
verification of auxiliary data (age) failed
RFID_ERROR_SESSION_INVALID_AUX_DATA_COMMUNITY_ID
verification of auxiliary data (Community ID) failed
RFID_ERROR_SESSION_E_SIGN_REQUIRES_APP_SELECTION
selection of eSign application is required to access its functionality
RFID_ERROR_SESSION_E_SIGN_PIN_NOT_SET
it is required to set the value of eSign-PIN for the current session
RFID_ERROR_SESSION_E_SIGN_PIN_NOT_VERIFIED
it is required to execute verification of eSign-PIN for the current session
RFID_ERROR_SESSION_INCORRECT_DATA
incorrect session object data
RFID_ERROR_SESSION_FILE_NOT_ENOUGH_DATA
no sufficient data for creation of the file contents ASN.1 object.
RFID_ERROR_SESSION_FILE_INCORRECT_DATA
incorrect data of the file contents ASN.1 object
RFID_ERROR_SESSION_FILE_UNEXPECTED_DATA
in compliance of the structure of the file contents ASN.1 object with the structure given in the respective specification
RFID_ERROR_SESSION_FILE_CONTENTS_UNEXPECTED_DATA
in compliance of the structure of the formed ASN.1-objects with the requirements of specification (in the context of specific file)
RFID_ERROR_SESSION_FILE_WRONG_TAG
incorrect value of the data group tag
RFID_ERROR_SESSION_FILE_CANT_USE_DATA
use of the read data is impossible
RFID_ERROR_SESSION_FILE_CANT_READ_DATA
error of physical data reading
RFID_ERROR_SESSION_FILE_ACCESS_DENIED
error of access to the protected data groups
RFID_LAYER6_SECURITY_MANAGER
secure communication channel organization is required to access data
RFID_LAYER6_APP_SELECTION_FAILURE
error of executing APDU-command of Master File or application selection
RFID_LAYER6_MUTUAL_AUTH_MAC_FAIL
error of the cryptogram checksum validation during BAC procedure
RFID_LAYER6_MUTUAL_AUTH_ENC_FAIL
error of the cryptogram validation during BAC
RFID_LAYER6_MUTUAL_AUTH_FAILURE
one of the errors of the APDU-commands:
  • Mutual Authenticate - performing the BAC
  • General Authenticate - at the 4th step of PACE performance
  • General Authenticate - performing the CA
RFID_LAYER6_SM_DO8E_MISSING
absence of the checksum in the protected APDU-response from the RFID-chip (SM '8E' data object)
RFID_LAYER6_SM_DO87_MISSING
absence of the data padding object in the protected APDU-response from the RFID-chip (SM '87' data object)
RFID_LAYER6_SM_DO99_MISSING
absence of the command execution status in the protected APDU-response from the RFID- chip (SM '99' data object)
RFID_LAYER6_SM_MAC_INCORRECT
error of the checksum validation of the protected APDU-response from the RFID-chip
RFID_LAYER6_SM_DO87_INCORRECT
incorrect contents of the data padding object in the protected APDU-response from the RFID-chip (SM '87' data object)
RFID_LAYER6_NON_TLV_RESPONSE_DATA
response to Read Binary APDU-command, using 'B1' parameter for file data reading with an offset >32767, is not represented in the TLV-format
RFID_LAYER6_WRONG_RND_ICC_LENGTH
incorrect length of the data received as a result of Get Challenge APDU-command execution
RFID_LAYER6_INT_AUTH_FAILURE
error of Internal Authenticate APDU-command execution when performing AA procedure
RFID_LAYER6_MSE_SET_KAT_FAILURE
error of MSE:Set KAT APDU-command execution when performing CA procedure, version 1
RFID_LAYER6_MSE_SET_DST_FAILURE
error of MSE:Set DST APDU-command execution when performing TA procedure
RFID_LAYER6_PSO_CERTIFICATE_FAILURE
error of PSO:Verify Certificate APDU-command execution when performing TA procedure
RFID_LAYER6_GET_CHALLENGE_FAILURE
error of Get Challenge APDU-command execution
RFID_LAYER6_EXT_AUTH_FAILURE
error of External Authenticate APDU-command execution when performing TA procedure
RFID_LAYER6_GENERAL_AUTH_FAILURE
error of General Authenticate APDU-command execution when performing PACE procedure at steps 1-3
RFID_ERROR_FAILED
error of operation execution (common case)
Last modified 1mo ago
Copy link